Please read first: Free guide and templates to help you prepare. This is not legal advice and does not guarantee compliance; Washington L&I offers free consultations. Always check the current rule text yourself — it is linked at the bottom of this page.
The short answer
Under WAC 296-880-10020(1), the employer must develop and implement a written fall protection work plan covering each area of the workplace where employees are assigned and where fall hazards of ten feet or more exist. The plan must cover seven things (subsection (2)(a)–(g), listed below), it must be available on site for the department to inspect, and before any employee enters an area with a fall hazard of ten feet or more, the employer must make sure the employee is trained and instructed in the plan's contents (subsection (3)).
First, an update: the rule moved
Older forms, binders and citations refer to WAC 296-155-24611 — that is where this requirement used to live. Washington consolidated its fall protection rules into chapter 296-880 WAC, the unified safety standards for fall protection, effective October 1, 2020. Chapter 296-155 WAC now carries a note saying that fall protection requirements for construction have been moved to chapter 296-880 WAC. The work plan rule today is WAC 296-880-10020, titled "Fall protection work plan required at ten feet or more." If your paperwork still cites 296-155-24611, the duty did not disappear — its address changed.
The 7 things the plan must cover — WAC 296-880-10020(2)
(a) Identify the hazards
Identify all fall hazards in the work area — the actual edges, openings, surfaces and tasks of this job, not fall hazards in general.
(b) Name the method
Describe the method of fall arrest or fall restraint to be provided for the work.
(c) System procedures
Describe the proper procedures for the assembly, maintenance, inspection, and disassembly of the fall protection system to be used.
(d) Tools and materials
Describe the proper procedures for the handling, storage, and securing of tools and materials.
(e) Overhead protection
Describe the method of providing overhead protection for workers who may be in, or pass through, the area below the work area.
(f) Removing an injured worker
Describe the method for prompt, safe removal of injured workers.
(g) On site, available
The plan must be available on-site for inspection by the department. A plan that lives in the office across town is not available.
Read item (b) carefully. A plan that exists but does not describe the method of fall arrest or fall restraint for the actual work is the classic failure mode — Washington employers have been cited on exactly that gap. The plan has to match the job in front of the crew: this roof, these anchors, this system.
The training duty — subsection (3)
The plan is not a document you file and forget. Subsection (3) requires that, prior to permitting employees into areas where fall hazards of ten feet or more exist, the employer must ensure employees are trained and instructed in the items described in subsection (2)(a) through (f) — the hazards, the method, the system procedures, the material handling, the overhead protection, and the injured-worker removal method. In practice: the crew hears the plan for their area, in a language they understand, before they go up — and a signed record of that instruction is how you show it happened.
Two things the 10-foot number does not mean
It does not mean "no plan needed below 10 feet, so nothing is needed"
Ten feet is the trigger for the written work plan. Other fall protection duties in chapter 296-880 WAC start lower: WAC 296-880-200 covers fall protection required at four feet or more for many surfaces, and WAC 296-880-30005 sets a six-foot trigger for fall arrest, restraint or positioning systems during low-pitch roofing work and leading-edge construction, and ten feet for structural-member erection and certain excavation work. The height that governs your task depends on the task.
It does not apply where guardrails remove the hazard
The note to WAC 296-880-10020 states that a fall protection work plan is not required where the use of a guardrail system eliminates the fall hazard. The rest of the fall protection rules still apply to the work itself — the note removes the plan duty, not the protection duty.
What an inspector will ask for
The work plan paper trail
- The written plan itself, on site, covering this work area (subsection (2)(g))
- All fall hazards in the area identified in the plan (subsection (2)(a))
- The fall arrest or restraint method described — for this job, not in general (subsection (2)(b))
- Assembly, maintenance, inspection and disassembly procedures described (subsection (2)(c))
- Tool and material handling, storage and securing procedures (subsection (2)(d))
- Overhead protection method for people below (subsection (2)(e))
- Method for prompt, safe removal of an injured worker (subsection (2)(f))
- Evidence the crew was trained and instructed in the plan before entering the area (subsection (3))
Where toolbox talks and attendance logs fit
Subsection (3) makes instruction part of the rule: the crew must be trained and instructed in the plan before they enter the area. A documented fall protection toolbox talk — run against the plan for today's area, in English and Spanish for a bilingual crew, with a signed attendance log naming the topic, the trainer, the date and everyone who was there — is the working record of that instruction. Our free Fall Protection Toolbox Talk outline shows how to run that talk in about 10 minutes. Be clear about the limit: a talk and a log support the training element. They are not a fall protection work plan, they do not write yours, and the plan itself must still be developed for each area where the 10-foot hazard exists.
Fall Protection is talk #1 of twelve — ready to run, in English and Spanish
The BuildPaperwork Safety Pack gives you 12 ready-to-run toolbox talks — Fall Protection, Ladders & Stairways, PPE Basics, Electrical Safety, Scaffolding, Heat Illness Prevention, Excavation & Trenching, Power Tool Safety, Forklift Awareness, Slips, Trips & Falls, Hazard Communication, and Emergency Action & First Aid — each in English and Spanish, with printable attendance log sheets for the instruction record. Delivered by email, ready to print. To be clear about what it is not: it does not include a fall protection work plan, and it does not replace writing yours for each job.
Monthly adds new topics over time and updated sheets when rules change; cancel anytime and keep what you downloaded. Prefer to look first? See everything that's inside the pack or build a sign-in sheet in the free Attendance Sheet Generator.
Frequently asked questions
At what height does Washington require a written fall protection work plan?
Ten feet or more — WAC 296-880-10020(1). Other fall protection duties begin at lower heights for some tasks, but ten feet is the written-plan trigger.
What happened to WAC 296-155-24611?
It moved. Fall protection rules were consolidated into chapter 296-880 WAC effective October 1, 2020; the work plan rule is now WAC 296-880-10020. Chapter 296-155 WAC carries a note pointing to the new chapter.
What must the plan include?
The seven items in subsection (2)(a)–(g): all fall hazards identified; the fall arrest or restraint method; system assembly, maintenance, inspection and disassembly procedures; tool and material handling procedures; overhead protection below; injured-worker removal; and the plan available on site.
Do workers have to be trained on the plan?
Yes — before they enter an area with fall hazards of ten feet or more, the employer must ensure they are trained and instructed in items (2)(a) through (f) (subsection (3)).
When is a work plan not required?
Where the use of a guardrail system eliminates the fall hazard, per the note to WAC 296-880-10020. The protection duties in the rest of the chapter still apply.
Does the BuildPaperwork Safety Pack include a fall protection work plan?
No. The pack is toolbox talks and attendance logs. It supports the training-and-instruction element of the rule; your work plan is a separate, job-specific document you develop for each area.
Sources
Every requirement above comes from the official rule text: WAC 296-880-10020, Fall protection work plan required at ten feet or more (Washington State Legislature), with the move note in chapter 296-155 WAC, Part C-1. Read the current version there before you rely on this summary — rules change, and the rule, not this page, is what an inspector enforces. Washington L&I (DOSH) also offers free consultations if you want the department's own help with your plan.
Free guide and templates to help you prepare. This is not legal advice and does not guarantee compliance; Washington L&I offers free consultations. BuildPaperwork sells training materials and document templates — not legal advice. These materials are not an OSHA 10/30 card, and BuildPaperwork is not affiliated with OSHA or with Washington L&I. Questions: contact@buildpaperwork.com · Portland, OR.